Size: 1505
Comment: update IPMI/iDRAC info
|
Size: 1776
Comment: Added SOL instruction (partly)
|
Deletions are marked like this. | Additions are marked like this. |
Line 7: | Line 7: |
* JBOD cards candidates * Model SAS3082E-R (IT mode) no support for large (>2TB) SATA drives (SAS should work, not verified) * Model LSI 9211-8i (IT mode) support verified |
* Drives Control: Model LSI 9211-8i (IT mode) |
Line 19: | Line 17: |
* Or use SOL for text console | |
Line 20: | Line 19: |
* Serial-Over-Lan 1. In BIOS setting change Serial Communication to '''On with Console Redirection via COM2''' and External Serial Connector to '''Serial Device 2''', leave else as default 2. (To Be Completed, grub and systemd's agetty service) |
|
Line 27: | Line 29: |
* [[https://i.dell.com/sites/csdocuments/Shared-Content_data-Sheets_Documents/en/R710-SpecSheet.pdf|documentation]] | * SAS3082E-R (IT mode): no support for SATA drives larger than 2TB (SAS should work, not verified) * [[https://i.dell.com/sites/csdocuments/Shared-Content_data-Sheets_Documents/en/R710-SpecSheet.pdf|Dell documents]] |
This is a provisional page about the Dell R710 machines.
Hardware
- CPU: 2x2.66GHz
- Memory: 12x4GB DIMM@1333MHz, 18slots each available
- Remote Control: iDRAC6 Enterprise
- Drives Control: Model LSI 9211-8i (IT mode)
- Interactive LCD with fault report
Software
- UEFI/BIOS: version 6.6.0 (latest)
- Lifecycle controller: 1.7.5.4/1.6.0
- iDRAC firmware: 2.92
- under VLAN1 (mgmt)
to use the virtual console, need Javaws (iced-tea works), and change of Java security configuration.
Alternative (may work): Supermicro IPMI Utilities or dockerized iDRAC console
- Or use SOL for text console
- IPMI v2
- Serial-Over-Lan
In BIOS setting change Serial Communication to On with Console Redirection via COM2 and External Serial Connector to Serial Device 2, leave else as default
- (To Be Completed, grub and systemd's agetty service)
Machine tasks
- They will be deployed as our new backup servers
- One will stay on-site, sync with production servers in real-time
- The other one will be deployed off-site (Thank you [TRS] for negotiation), synced at night
- The twin Dells will be constructed as identical for easier debug/recovery
Additional information
- SAS3082E-R (IT mode): no support for SATA drives larger than 2TB (SAS should work, not verified)